The offered product is a modular OLT transmitting terminal designed for operation in passive networks (PON). The enclosure is adapted for installation in a 19" Rack cabinet and features 7 slots to which line cards can be connected. The set includes two H903PILA power supply modules; the nominal input voltage is -48 / -60 V DC (full range -38.4 ~ -72 V DC), while the maximum power consumption depends on the type and number of line cards used. The MA5800-X7 is equipped with 2 H901MPLH-G01 control boards, which also serve as uplink boards. Each control board features 2 QSFP28 slots with a throughput of 100 Gb/s and 4 SFP28 slots with a throughput of 1 / 10 / 25 Gb/s. In total, it can support up to 786432 MAC addresses and 34816 ONTs / multicast users, which translates into significantly greater capabilities than those offered by MPLG boards.
The set includes:
- 2 H901MPLH-G01 control boards (2x 100G, 4x 25G);
- 2 H903PILA power supply boards (input -48 / -60 V DC);
- H90F3FMMA fan board;
- H90Z1BPMB service shelf;
- chassis;
- accessories.
MPLH-G01 Control Board
The set includes two MPLH-G01 control boards, which offer higher throughput and significantly greater capabilities than the older MPLA / MPLB / MPLG models. They support twice as many multicast users and three times as many MAC addresses.
The MPLG-G01 is equipped with 2 QSFP28 uplink slots with a throughput of 100 Gb/s and 4 SFP28 slots with a throughput of 1 / 10 / 25 Gb/s. Thanks to such a large number of high-speed interfaces, the offered product is perfectly suited for XGS-PON networks and will allow the delivery of very large data packages to customers.


H903PILA Power Supply Board
Power is provided by two H903PILA power supply boards, which nominally support -48 and -60 V DC. The modules are designed for redundant operation — in the event of a failure of one module, the other takes over to ensure power continuity.
First startup
Specifications
| Huawei MA5800-X7 | |
| General features | |
|---|---|
| Slots |
Control board slots: 8, 9 Service board or upstream interface board slots: 1 – 7 Universal interface board slot: 0 Power board slots: 10, 11 |
| Dimensions (W x D x H) (mm) |
Excluding mounting ears: 442 x 268.7 x 263.9 Including IEC mounting ears: 482.6 x 268.7 x 263.9 |
| Maximum weight (including mounting brackets) | 26 kg |
| Ambient temperature |
–40°C to +65°C The MA5800 can start up at a lowest temperature of –25°C. |
| Ambient humidity | 5%-95% RH |
| Atmospheric pressure | 70 - 106 kPa |
| Payload switching capacity of the control board (load sharing mode) | 8 Tb/s |
| Maximum payload bandwidth per service slot (load sharing mode) | 200 Gb/s |
| H901MPLH-G01 Main Processing Board | |
| Bandwidth per slot (load sharing mode) | 200 Gb/s |
| Upstream or cascading port |
2x QSFP28 100 Gb/s 4x SFP28 1 / 10 / 25 Gb/s |
| Maximum number of MAC addresses | 786432 |
| Access ONTs | 34816 |
| Multicast users | 34816 |
| Static programs | 8192 |
| Online programs |
IPv4: 8000 IPv6: 2000 |
| Service ports | 139264 |
| IPv4 routing table size | 65536 |
| IPv6 routing table size | 16384 |
| ARP table size | 131072 |
| ND table size | 16384 |
| Sync ETH clock | Yes |
| 1588ACR | No |
| 1588v2 Synchronization | Yes |
| 9216-byte jumbo frames | Yes |
| Temperature query and hightemperature alarm | Yes |
| Dimensions without packaging (H x W x D) [mm] | 399.1 x 31 x 258.9 mm |
| Weight without packaging [kg] | 2.283 kg |
| Static power consumption [W] | 131 W |
| Maximum power consumption [W] | 175 W |
| Operating temperature [°C] | -40°C to 55°C |
| H903PILA (Power Transfer Board) | |
| Dimensions without packaging (H x W x D) [mm] | 97.5 x 25.4 x 253 mm |
| Weight without packaging [kg] | 0.43 kg |
| Number of power inputs | 1 |
| Rated input voltage | -48 / -60 V DC |
| Input voltage range | -38.4 ~ -72 V DC |
| Static power consumption [W] | 0.7 W |
| Maximum power consumption [W] | 5.5 W |
| Operating temperature [°C] | -40°C to 65°C |
| Board detection | Yes |
| Filtering and current-limiting for the power input port |
Yes |
| Detection of protection fuse faults | Yes |
| Protection alarm | Yes |
| Detection of power input | Yes |