0,26 € netto
SinusPRO-2000 W is a device that combines the functionality of a computer backup power supply, inverter, UPS switch, mains voltage stabilizer (AVR) and a battery charger. It is equipped with an AC / SOLAR operation priority switch, it has appropriate protections, thanks to which it can cooperate with a solar regulator and photovoltaics. The DC input voltage is 24 V and the output power is 1400 W (2000 W overload power).
The offered product is used for uninterrupted power supply to devices. The output current is sinusoidal, not square, as is the case with IPS inverters. Thanks to this, it is possible to power sensitive systems without the risk of damaging them. In the event of a power failure, sinusPRO automatically switches to solar or battery power. It is possible to mount the product on the wall.
Warning! SinuSPRO-2000 W does not have a built-in solar regulator!
The most important features:
- DC input voltage: 24V;
- continuous output power 1400 W (2000 W instantaneous);
- UPS emergency switch functionality;
- the ability to work with a solar controller and photovoltaics;
- AC / SOLAR work priority switch;
- functionality of the mains voltage stabilizer;
- battery charger.
Download: [manual]
Specification
sinusPRO-2000 W | |
Rated power (continuous) | 1400 W |
Overload power (instantaneous) | 2000 W |
Battery voltage | 24 V |
Rectifier (charging current) | 20 A |
PV charging voltage |
~36 V 24 - 50 V |
Solar regulator | not included |
Automatic mains voltage regulator - AVR | 140 - 275 V AC |
current consumption without load | from 0,3 A to 1,5 A |
Admissible range of supply voltage | Switching over to battery power supply occurs when the mains voltage is lower than 160 V ± 5 V or higher than 260 V ± 5 V |
Supply voltage frequency | 45 - 65 Hz |
The frequency of the UPS output voltage | 50 Hz (± 0,5 Hz) |
Output voltage range |
Mains voltage regulator AVR: 204 - 240V Uninterruptible Power Supply UPS / Battery: 230V (± 3%) |
Overload protection (battery powered) |
in case of 110% -130% overload, the power is disconnected after 30 seconds. If the overload is greater than 130%, the power is disconnected immediately. |
Overload protection (mains supply) | The device warns of an overload until the fuses blown. |
Permissible air humidity | 10%-90% RH |
Permissible working temperature | From 0 to 40 °C |
Dimensions | 310x170x330 mm |
Weight | 14 kg |