Solarix SXKD-7A-1200-SSTP-LSOH SSTP cat. 7A LSZH Cca-s1,d1,a1 500m
Marca: Solarix
Código de producto: SOL-SXKD-7A-12SSTPLS
Número de catálogo: 7731
Garantía (meses):

Product on demand

Precio
412,60
507,50IVA incluido
Cantidad
-
+
favoriteAñadir a la lista de deseos
Descripción

Installation Cable Solarix Category 7A SSTP LSOH Cca s1 d1 a1 1,200 MHz

These Solarix double shielded installation cables comply with the most stringent structured cabling specifications. They easily exceed the requirements specified in the ISO/IEC 11801 and EN 50173 standards for Category 7A/Class FA cables. Selected design of these cables goes hand-in-hand with the best quality which, with strictly controlled production, guarantees the highest performance. The Solarix Category 7A installation cables are produced in S-STP configuration and are tested up to 1,200 MHz. Their excellent performance ensures full compatibility with all new high-speed data protocols, such as 10GBASE-T. Foamed PE insulated conductors have the pairs shielded by aluminium foil and copper braid. Sheath material is supported by fire retardant, low smoke, halogen free, and CPR rated compounds – i.e. LSOH (reaction  to fire Cca s1 d1 a1) and LSOHFR (reaction to fire B2ca s1 d1 a1).

Specification:

SXKD-7-SSTP-LSOHFR
LSOH Sheath Reaction to fire Cca s1 d1 a1
Applicable Standards iSo/ieC 11801, ieC 61156-5, eN 50173-1, eN 50173-2, eN 50288-9-1
Conductor Type and Size Bare copper wire 0.58 mm ± 0.005 mm
Insulation Skin-foam-skin PE
Wire Diameter with Insulation 1,35 mm
Cable Diameter 7,8 mm
Weight 59 kg/km
Colour Orange RAL 2003
NVP 79%
Propagation delay 480 ns/100 m
Delay skew ≤ 25 ns/100 m
Storage Temperature -20 to +60 °C
Operation Temperature -20 to +60 °C
Installation Temperature 0 to +50 °C
Installation Cables Transmission Characteristics (at 20°C)
f (MHz) Attentuation (dB/100m) NEXT (dB) PSNEXT (dB) Prop. delay (ns/100m) ACR-F (dB/100m) PSACR-F (dB/100m)

Return loss

(dB)

1 1,96 101,31 98,99 479,69 100,33 97,29 32,15
4 3,55 99,51 97,53 462,20 97,74 94,19 34,86
10 5,49 98,28 96,15 455,77 95,54 92,37 40,24
16 7,01 98,32 95,32 453,46 94,81 91,49 39,79
20 7,91 98,90 95,96 452,53 94,95 91,63 42,29
25 8,92 97,99 95,49 451,71 93,53 91,75 41,44
31,25 10,05 102,41 99,82 450,97 97,39 94,81 41,75
62,5 14,38 99,54 97,18 449,14 92,35 89,47 36,67
100 18,24 98,38 96,39 448,21 89,26 86,53 37,54
200 25,99 96,46 94,12 447,18 83,47 80,83 33,34
250 29,18 97,03 95,54 446,92 82,44 79,83 37,69
300 32,09 93,29 91,28 446,73 77,25 94,33 29,27
400 37,27 85,50 83,70 446,46 66,87 62,98 30,36
500 41,88 83,76 81,54 446,27 62,82 59,76 27,87
600 45,96 84,49 81,92 446,07 61,51 59,50 25,62
1000 60,09 81,45 78,85 444,93 51,41 49,07 22,33
1200 61,29 80,80 77,69 444,92 50,16 47,95 20,30