Solarix SXKD-6A-STP-LSOHFR STP cat. 6A LSZH Bca-s1,d1,a1 500m
Marca: Solarix
Código de producto: SOL-SXKD-6A-STPLSOHF
Número de catálogo: 7720
Garantía (meses):
Precio
313,76
385,92IVA incluido
Cantidad
-
+
favoriteAñadir a la lista de deseos
Descripción

Installation Cable Solarix Category 6A STP LSOHFR B2ca s1 d1 a1

These Solarix cables for Category 6A and Class EA systems are manufactured to the highest quality standards. They easily exceeds the performance specifications for Category 6A/Class EA defined in the ANSI/TIA 568, ISO/IEC 11801, and EN 50173 standards for Category 6A/Class EA. The Solarix Category 6A installation cables are designed using high performance materials and special aluminum foil shielding around each individual pair to guarantee maximum reliability. The cables are tested up to 500 MHz and therefore ensure excellent Alien Cross Talk elimination. These Category 6A/Class EA cables are especially suitable for all new high-speed and high-bandwidth data protocols, such as 10GBASE-T. Sheath material is supported by fire retardant, low smoke, halogen free, and CPR rated compounds – i.e. LSOH (reaction to fire Dca s1 d2 a1 and Dca s2 d2 a1), LSOHFR (reaction to fire B2ca s1 d1 a1), and PE (reaction to fire Fca)  for outdoor cables.

Specification:

SXKD-6A-STP-LSOHFR
LSOHFR Sheath Reaction to fire B2ca s1 d1 a1
Applicable Standards ISO/IEC 60754-2, IeC 61034-2, IeC 60332-1-2,eN 50575, eN 13501,
Conductor Type and Size Bare copper wire 0.56 mm ± 0.005 mm
Insulation Skin-foam-skin PE
Wire Diameter with Insulation 1,33 mm
Cable Diameter 7,5 mm
Weight 55 kg/km
Colour Orange RAL 2003 (LSOHFR)
NVP 75 %
Propagation delay 480 ns/100 m
Delay skew ≤ 45 ns/100 m
Storage Temperature -20 to +60 °C
Operation Temperature -20 to +60 °C
Installation Temperature 0 to +50 °C
Solarix Category 6A Installation Cables Transmission Characteristics (at 20 °C)
f (MHz) Attenuation (dB/100m) NEXT (dB) PSNEXT (dB) Prop. delay (ns/100m) ACR-F (dB/100m) PSACR-F (dB/100m)

Return Loss

(dB)

1 1,98 93,94 91,70 479,69 92,01 82,99 31,08
4 3,59 96,68 93,19 462,20 94,10 90,15 35,28
8 4,95 93,93 90,89 457,08 92,04 87,80 33,99
10 5,52 94,69 91,36 455,77 89,01 86,57 33,22
16 7,03 93,18 90,17 453,46 87,03 83,49 33,46
20 7,92 88,94 87,46 452,53 88,22 85,63 30,52
25 8,95 96,08 93,46 451,71 84,24 81,75 31,56
31,25 10,08 96,06 91,93 450,97 83,40 81,59 31,32
62,5 14,38 92,33 88,01 449,14 78,01 74,47 35,29
100 18,25 87,75 85,05 448,21 75,83 71,53 31,44
200 26,08 78,52 74,34 447,18 60,74 57,83 33,21
250 29,26 74,26 69,77 446,92 61,21 57,76 31,07
300 32,16 72,36 68,57 446,73 58,66 55,13 29,67
400 37,54 69,07 67,07 446,46 43,60 41,58 27,03
500 42,26 72,83 70,26 446,27 42,92 39,76 23,32