Contacto
closeContacto
RMADetalles de envíoPruebas de productos Términos y condiciones

Contacto:

alternate_emailtienda@cdr.pl

call+48 32 750 5003

lun - vier 9:00 - 17:00

Contacto

Cuenta
closeIniciar sesión
Iniciar sesión

Nuevo cliente?

Crear cuenta
Carrito
closeCarrito
La cesta está vacía favoriteWishlist
Solarix SXKD-7-SSTP-LSOH SSTP cat. 7 LSOH Cca-s1,d1,a1 500m
Marca: Solarix
Código de producto: SOL-SXKD-7-SSTP-LSOH
Número de catálogo: 7726
Garantía (meses):

Towar dost?pny na zamówienie

Precio
329,73
405,57IVA incluido
Cantidad
-
+
favoriteAñadir a la lista de deseos
Descripción

Installation Cable Solarix Category 7 SSTP LSOH Cca s1 d1 a1 1,000 MHz

These Solarix double shielded installation cables comply with the most stringent structured cabling specifications. They easily exceed the requirements specified in the ISO/IEC 11801 and EN 50173 standards for Category 7/Class F cables. Selected design of these cables goes hand-in-hand with the best quality which, with strictly controlled production, guarantees the highest performance. The Solarix Category 7 installation cables are produced in S-STP configuration and are tested up to 1,000 MHz. Their excellent performance ensures full compatibility with all new high-speed data protocols, such as 10GBASE-T. Foamed PE insulated conductors have the pairs shielded by aluminium foil and copper braid. Sheath material is supported by fire retardant, low smoke, halogen free, and CPR rated compounds – i.e. LSOH (reaction  to fire Cca s1 d1 a1) and LSOHFR (reaction to fire B2ca s1 d1 a1).

Specification:

SXKD-7-SSTP-LSOH
LSOH Sheath Rreaction to fire Cca s1 d1 a1
Applicable Standards iSo/ieC 11801, ieC 61156-5, eN 50173-1, eN 50173-2, eN 50288-4-1
Conductor Type and Size Bare copper wire 0.565 mm ± 0.005 mm
Insulation Skin-foam-skin PE
Wire Diameter with Insulation 1,33 mm
Cable Diameter 7,6 mm
Weight 56 kg/km
Colour Orange RAL 2003
NVP 79%
Propagation delay 480 ns/100 m
Delay skew ≤ 25 ns/100 m
Storage Temperature -20 to +60 °C
Operation Temperature -20 to +60 °C
Installation Temperature 0 to +50 °C
Installation Cables Transmission Characteristics (at 20 °C)
f (MHz) Attentuation (dB/100m) NEXT (dB) PSNEXT (dB) Prop. delay (ns/100m) ACR-F (dB/100m) PSACR-F (dB/100m)

Return loss

(dB)

1 1,96 98,22 96,47 479,69 92,01 89,29 32,15
4 3,55 98,45 96,63 462,20 94,10 90,15 34,86
8 4,92 99,07 95,11 457,08 92,04 87,80 36,92
10 5,49 98,60 95,06 455,77 89,01 86,57 40,24
16 7,01 99,49 96,52 453,46 87,03 83,49 39,79
20 7,91 97,23 95,86 452,53 88,22 85,63 42,29
25 8,92 97,96 95,89 451,71 84,24 81,75 41,44
31,25 10,05 98,64 96,82 450,97 83,40 81,59 41,75
62,5 14,39 96,18 93,18 449,14 78,01 74,47 36,67
100 18,22 97,26 93,39 448,21 75,83 71,53 37,54
200 26,02 96,49 94,12 447,18 60,74 57,83 33,34
250 29,18 95,04 91,54 446,92 61,21 57,76 37,69
300 32,10 92,84 90,28 446,73 58,66 55,13 29,27
400 37,50 91,83 89,70 446,46 43,60 41,58 30,36
500 42,18 94,49 91,54 446,27 42,92 39,76 27,87
600 44,19 83,14 81,92 446,07 43,51 41,25 25,62
1000 59,32 67,34 65,20 444,93 38,05

35,07

22,33